Inline ejectors
Type »VR« and Type »SLP«

For vacuum generation directly at the point of use.
For direct installation between the suction pad and the compressed air supply.

Purely pneumatic vacuum generator that operates on the Venturi principle.
Compressed air enters the ejector and flows through a nozzle. This results in a vacuum
immediately behind the nozzle outlet, and air is drawn in through the vacuum inlet.
This air and the driving air leave the ejector and enter the atmosphere via the exhaust air outlet.

Characteristics

- Vacuum generator with a high maximum vacuum value (85%)
- No moving parts, which means no wear and no maintenance
- Extremely space-saving installation, ideal where space is restricted
- Minimum compressed air consumption
- Low noise output

Applications - Direct installation on the suction pad by screwing / plugging into the
distribution beam
- Handling all kinds of workpiece
Body Anodised aluminium (type VR)
Plastic (type SLP)
Nozzle system Brass (type VR)
Connection Screw or plug connection
More information Data sheet

VR 07
Inline ejectors »VR«, screw connection
Art. No. Nozzle
size
Compressed
air inlet
Vacuum
inlet
Exhaust
air outlet
Length Price €
VR 07 0.7 G 1/4 female G 1/8 female M 5 male 35 30,55
  Price: 30,55 EUR, Discount: 0,00%, Price increment: 0,00%This article is available immediately 
VR 09 0.9 G 1/4 female G 1/8 female M 5 male 35 30,55
  Price: 30,55 EUR, Discount: 0,00%, Price increment: 0,00%This article is available immediately 
Inline ejectors »SLP«, plug connection
Art. No. Nozzle
size
Compressed
air inlet
Vacuum
inlet
Exhaust
air outlet
Length Price €

SLP 07
SLP 05 0.5 4 mm 4 mm - 57 19,00
  Price: 19,00 EUR, Discount: 0,00%, Price increment: 0,00%This article is available immediately 
SLP 07 0.7 4 mm 4 mm - 57 19,95
  Price: 19,95 EUR, Discount: 0,00%, Price increment: 0,00%This article is available immediately 
Click here for socket connectors suitable for vacuum (»click-clock« series)
All PA/PE/PU hoses up to size 12 x 9 mm are suitable for vacuum
Technical data: Inline ejectors VR and SLP
Type Degree of evacuation
[%]
Max. suction rate
[l/min]
Air consumpt. during evac.
[l/min]
Operating pressure Weight
[kg]
VR 07 90 14.0 21.0 5 bar 0.015
VR 09 89 21.0 36.0 5 bar 0.015
SLP 05 85 8.0 13.0 4.5 bar 0.005
SLP 07 85 16.0 25.0 4.5 bar 0.005

Back to overview

Art. No.